 MPDTH***10 Series
Adjustable Non-isolated 12/15-Amp POLA DC/DC Converters
DESCRIPTION
The MPDTH series non-isolated DC/DC power modules are small in size but big on performance and flexibility. Their high output current, compact footprint and industry-leading features offer system designers versatile modules for powering complex multi-processor digital systems. Standard inputs are 3.3V., 5V. or 12 Volts DC nominal.
Typical units
FEATURES
Compatible to Point-of-Load Alliance (POLA) Specifications Surface-mount or through-hole small footprint package Three user-selectable output voltage ranges covering 0.8V to 5.5V Outline dimensions less than one square inch 3.3V, 5V and 12 Vdc nominal inputs High efficiency up to 95 % typical Tracking input for sequenced startup/shutdown Sense input for load accuracy compensation Outstanding thermal performance and derating -40 to +85 degrees Celsius operating range Extensive self-protection, voltage limits and short circuit features On/Off control, trim, margin controls and pre-bias start-up functions
Two mounting styles are offered, either a pinned through-hole model with slightly lower height or a surface mount model, both with identical length and width. Respective models all share the same pinout and comply with the POLA DC/DC converter standard. The output voltage is adjustable in three ranges from 0.8 V. to 5.5 V and can be set with a single external resistor. Margin controls provide a fixed step to the output voltage either 5% up or down. The series also includes Auto-Track sequencing, enabling modules to track each other's output voltage in multipowered systems during power-up and power-down. Other operating features include a remote on/off control and the ability to start up into an existing (prebias) output voltage. Extensive self-protection features include input under-voltage lockout (UV), output short circuit protection and output overcurrent shutdown (OC) using an automatic restart. All models meet RoHS6 hazardous substance compliance.
VoSense Track Input
F1
+Vin 2 8 5 6
+Vout
C1 External DC Power Source
Inhibit On/Off
MPDTH_10 Series
3 9 10 Grounds Margin Down Margin Up 71
VoAdj (Trim) 4
Open = On Closed = Off D1
Figure 1. Connection Diagram
Notes: 1. Murata Power Solutions strongly recommends an external fuse, F1. Fuse rating = 2 x Iin max. 2. Consider using diode D1 to blow the fuse in case of reversed polarity. 3. C1: 470F/25V, aluminum electrolytic capacitor, required for MPDTH03010, 05010 models. C1: 560F/25V, aluminum electrolytic capacitor, required for MPDTH12010 models. 4. Track input is referred to ground. 5. See trim information for RSet.
For full details go to www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPDTH_10 Series.A04 Page 1 of 6
MPDTH***10 Series
Adjustable Non-isolated 12/15-Amp POLA DC/DC Converters
SPECIFICATION SUMMARY AND ORDERING GUIDE
Vout (Volts)
0.8-2.5 0.8-2.5 0.8-3.6 0.8-3.6 1.2-5.5 1.2-5.5
Model Number
MPDTH03010WAH MPDTH03010WAS MPDTH05010WAH MPDTH05010WAS MPDTH12010WAH MPDTH12010WAS
Output Iout (Amps, Power max.) (Watts)
15 15 15 15 12 12 37.5 37.5 54 54 66 66
Ripple&Noise (mV pk-pk)
20(6) 20(6) 30(7) 30(7) 33(8) 33(8)
Regulation Line Load
1.25% 1.25% 1.25% 1.25% 1.25% 1.25% 1.5% 1.5% 1.5% 1.5% 1.5% 1.5%
Input (9) Vin nom. Range (Volts) (Volts)
3.3 3.3 5.0 5.0 12.0 12.0 3-3.6 3-3.6 4.5-5.5 4.5-5.5 10.8-13.2 10.8-13.2
Efficiency (%)
93(3) 93(3) 95(4) 95(4) 94(5) 94(5)
Case(inches)
1.37x0.62x0.35 1.37x0.62x0.38 1.37x0.62x0.35 1.37x0.62x0.38 1.37x0.62x0.35 1.37x0.62x0.38
Package Case(mm)
34.80x15.75x9.0 34.80x15.75x9.57 34.80x15.75x9.0 34.80x15.75x9.57 34.80x15.75x9.0 34.80x15.75x9.57
Type(2)
TH SM TH SM TH SM
Notes: All specifications are typical at nominal input line voltage, nominal output voltage and full load, Ta=+25 deg.C. unless otherwise noted. See detailed specifications. "TH" is a pinned through-hole package. "SM" is a surface mount package. Vin=3.3V, Vout=2.5V, Iout=10A Vin=5V, Vout=3.3V, Iout=10A
Vin=12V, Vout=5V, Iout=10A Vin=3.3V, Vout=2.5V, Iout=15A Vin=5V, Vout=3.3V, Iout=15A Vin=12V, Vout=5V, Iout=15A The minimum input voltage is +2.95V. Or (Vout + 0.65V.), whichever is greater. RoHS6 compliance does not claim EU RoHS exemption 7b (lead in solder).
MPDTH**010 Series Performance and Functional Specifications
All specifications are typical unless noted.
Input
Input Voltage Range Start-Up Voltage See Ordering Guide 2.45 Volts (MPDTH03010) 4.3 Volts (MPDTH05010) 9.5 Volts (MPDTH12010) 2.4 Volts (MPDTH03010) 3.7 Volts (MPDTH05010) 9.0 Volts (MPDTH12010) 470 F, required (MPDTH03010 and MPDTH05010) 560 F required (MPDTH12010) OFF = -0.2V to +0.8 V max. or ground pin ON = open pin (internal pullup) to +Vin -130 A (MPDTH03010 and MPDTH05010) [5] -240 A (MPDTH12010) [5] -130 A 1 Volt per mSec max. -0.3V to (+Vin + 0.3V) -5% or +5% adjustment of Vout when the respective margin control is grounded. Current, -8 A sink.
Ripple/Noise Line/Load Regulation Efficiency Maximum Capacitive Loading Cap-ESR>=0.004 Ohms Cap-ESR <0.004 Ohms Current Limit Inception Short Circuit Mode Protection Method Short Circuit Duration Sequencing VoSense Input
See Ordering Guide See Ordering Guide See Ordering Guide
Undervoltage Shutdown
8,250 F non-ceramic (MPDTH03010 and MPDTH05010) 6,600 F non-ceramic (MPDTH12010) 20 Amps
External Input Capacitor (See note 3) Remote On/Off Inhibit Control Positive Logic Inhibit Current (grounded) Tracking Input Current when grounded Slew rate Tracking Input Range Margin Controls
Autorecovery after overload removal Continuous, no damage (output shorted to ground) Start-up of multiple units may be synchronized by connecting tracking pins. (Vout - VoSense) < 0.3 Volts
Dynamic Characteristics
Dynamic Load Response 70 Sec to within 2% of final value (50 to 100% load step, 1A/Sec load step, 330 F external output cap) 300 KHz (MPDTH03010 and MPDTH05010) 350 KHz (MPDTH12010)
Switching Frequency
Output
Minimum Loading Nominal Accuracy Voltage Adjustment Range Temperature Coefficient No minimum load 2 % max. of Vsetting See Ordering Guide 40 ppm. per C. of Vout Operating Temperature Range Storage Temperature Range
Specification Notes: (1) All specifications are typical unless noted. General conditions for Specifications are +25 deg.C ambient, Vin=nominal, Vout=+2.5V, full load. Cin=470 mF (required for models MPDTH03010, 05010), Cout= 0 mF. For model MPDTH12010, the required input capacitor is 560 F. See note 3. Adequate airflow must be supplied for extended testing under power (2) An external output capacitor is not required. However, a 330 F output capacitor improves transient response. (3) The required input capacitor must have a ripple current rating of 700 mA RMS or greater for models MPDTH03010 and MPDTH05010. For model MPDTH12010, the ripple rating must be 800 mA RMS or greater. (4) Mean Time Before Failure is calculated using the Telcordia (Belcore) TR-332 50% stress, ground benign conditions, Tambient=+40 deg.C.
Environmental
Calculated MTBF [4] 5.7 million hours,min. (MPDTH03010 and MPDTH03010) 6.4 million hours,min. (MPDTH12010) -40 to +85 deg.C. (no condensation) -40 to +125 deg.C.
(5) Track input is grounded or equal to Vin. (6) There is no input protection against overvoltage or reversed polarity. Please provide proper fusing and a back-biased diode if there is the possibility of improper polarity. Refer to the Connection Diagram. (7) The outputs are not intended to sink appreciable reverse current. (8) Output current limit and short circuit protection is non-latching. When the overcurrent fault is removed, the converter will immediately recover. (9) Connect VoSense to Vout remotely at the load for optimal accuracy. If not used at the load, connect VoSense to Vout at the converter. Do not exceed 0.3 Volts difference between Vout and VoSense.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPDTH_10 Series.A04 Page 2 of 6
MPDTH***10 Series
Adjustable Non-isolated 12/15-Amp POLA DC/DC Converters
MECHANICAL SPECIFICATIONS
Surface Mount Models MPDTH_WAS
34.80 3.18 3.18 1.52 1 9.52 10 9 8 15.88 7 12.70 15.75 1.52 9.57 MAX
Through-hole Pins Models MPDTH_WAH
34.80 3.18 3.18 1.52 1 9.52 10 9 8 15.88 7 12.70 15.75 1.52 3.55
1.02 5 Places
PNY
Solder Ball 1.02 10 Places
PNH
2
3
4
5 TOP VIEW
6 9.00 MAX SIDE VIEW Host Board
2
3
4
5 TOP VIEW
6 SIDE VIEW
Dimensions are in mm.
Third Angle Projection
Dimensions are in millimeters.
PIN NUMBER AND FUNCTION Pin Function 1 2 Ground Input (Vin) Inhibit remote On/Off control Vout Adjust (trim) Vout Sense Pin 6 7 8 9 10 Function Output (Vout) Ground Track Input Margin Down Input Margin Up Input
Tolerances (unless otherwise specified): .XX 0.02 (0.5) .XXX 0.010 (0.25) Angles 2 Components are shown for reference only.
3 4 5
MAXIMUM SAFE OPERATING AREA (DERATING)
MPDTH03010
90 80 70
Ta - C
MPDTH05010
90 80
90 80
MPDTH12010
Ta - C
Ta - C
60 50 40 30 20 0 3 6
Natural Convection 100 LFM 200 LFM 400 LFM
70 60 50 40 30 20
Natural Convection 100 LFM 200 LFM 400 LFM
70 60 50 40 30 20
Natural Convection 100 LFM 200 LFM 400 LFM
9 Iout - Amps
12
15
0
3
6 Iout - Amps
9
12
15
0
2
4
6 Iout - Amps
8
10
12
Vout = 2.5V, Vin = 3.3V
Vout = 3.3V
Vout = 5.0V
Units soldered to a 4" x 4" 4-layer PCB with 1 oz. copper.
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPDTH_10 Series.A04 Page 3 of 6
MPDTH***10 Series
Adjustable Non-isolated 12/15-Amp POLA DC/DC Converters
PRINTED CIRCUIT LAYOUT PATTERN RECOMMENDATION
Surface Mount Models MPDTH_WAS
35.85 3.18 3.18 9.52
Through-hole Pins Models MPDTH_WAH
35.85 3.18 3.18 9.52
2.03
2.03
15.88
2.03
15.88
2.03 12.70
12.70
16.76
TOP VIEW
TOP VIEW
2.16 Min. 10 Places
1.4 Min. 10 Places Plated through hole.
Dimensions are in millimeters.
Dimensions are in millimeters.
EFFICIENCY VS. OUTPUT VOLTAGE
Models MPDTH03010WAS/WAH Vout 2.5 V. 2.0 V. 1.8 V. 1.5 V. 1.2 V. 1.0 V. Iout=10 Amps Efficiency (typ.) 93% 92% 91% 89% 87% 85% Rset Trim Resistor 2.21 K 4.12 K 5.49 K 8.87 K 17.4 K 36.5 K
Models MPDTH05010WAS/WAH Vout 3.3 V. 2.5 V. 2.0 V. 1.8 V. 1.5 V. 1.2 V. 1.0 V. Iout=10 Amps Efficiency (typ.) 95% 93% 92% 91% 90% 88% 86% Rset Trim Resistor 698 2.21 K 4.12 K 5.49 K 8.87 K 17.4 K 36.5 K
Models MPDTH12010WAS/WAH Vout 5.0 V. 3.3 V. 2.5 V. 2.0 V. 1.8 V. 1.5 V. 1.2 V. Iout=8 Amps Efficiency (typ.) 94% 93% 91% 90% 89% 88% 86% Rset Trim Resistor 280 2.0 K 4.32 K 8.06 K 11.5 K 24.3 K Open
EFFICIENCY VS. OUTPUT VOLTAGE AND LOAD CURRENT @ 25C
MPDTH03010W (Vin = 3.3V)
100 90
MPDTH05010W (Vin = 5V)
100 90
MPDTH12010W (Vin = 12V)
100 90
Efficiency (%)
80 Vout = 2.5 V 70 60 50 0 3 6 9 12 15 Vout = 1.8 V Vout = 1.2 V Vout = 1.0 V
Efficiency (%)
80 70 60 50 0 3 6
Vout = 3.3 V Vout = 2.5 V Vout = 1.8 V Vout = 1.2 V
Efficiency (%)
80 70 60 50
Vout = 5.0 V Vout = 3.3 V Vout = 2.5 V Vout = 1.8 V Vout = 1.2 V
Load Current (Amps)
9
12
15
0
2
4
6
16.76
8
10
12
Load Current (Amps)
Load Current (Amps)
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPDTH_10 Series.A04 Page 4 of 6
MPDTH***10 Series
Adjustable Non-isolated 12/15-Amp POLA DC/DC Converters
OUTPUT VOLTAGE ADJUSTMENT
The output voltage may be adjusted over a limited range by connecting an external trim resistor (Rset) between the VoutAdjust (trim) pin and Ground. The Rset resistor must be a 1/10 Watt precision metal film type, 1% accuracy or lower with low temperature coefficient, 100 ppm/C. or better. Mount the resistor close to the converter with short leads. In the tables below, the calculated resistance is given and an equivalent using two series-connected standard value resistors. Do not exceed the specified limits of the output voltage or the converter's maximum power rating when applying these resistors. Also, avoid high noise at the VoutAdjust input. However, to prevent instability, you should never connect any capacitors from VoutAdjust to either Ground or Vout.
Ground 10 K VoAdj pin in
Vout
Error Amplifier
in = 2.49 K, MPDTH03010 and MPDTH05010 in = 1.82 K, MPDTH12010
Figure 2. Vout Adjust Input Circuit
MPDTH03010WAS/WAH Output Voltage 2.5 V. 2.0 V. 1.8 V. 1.5 V. 1.2 V. 1.0 V. 0.8 V. Calculated Rset (K) 2.22 4.18 5.51 8.94 17.5 37.5 Standard value resistors 2 K + 220 3.9 K + 270 5.1 K + 390 8.2 K + 750 16 K + 1.5 K 36 K + 1.5 K Open
MPDTH05010WAS/WAH Output Voltage 3.3 V. 2.5 V. 2.0 V. 1.8 V. 1.5 V. 1.2 V. 1.0 V. 0.8 V. Calculated Rset (K) 0.71 2.22 4.18 5.51 8.94 17.5 37.5 Standard value resistors 680 + 30 2 K + 220 3.9 K + 270 5.1 K + 390 8.2 K + 750 16 K + 1.5 K 36 K + 1.5 K Open
MPDTH12010WAS/WAH Output Voltage 5.0 V. 3.3 V. 2.5 V. 2.0 V. 1.8 V. 1.5 V. 1.2 V. Calculated Rset (K) 0.29 1.99 4.33 8.18 11.51 24.85 Standard value resistors 270 + 20 2 K 4.3 K + 30 7.5 K + 680 11 K + 510 24 K + 820 Open
Rset (K) = 10 K x Vout0.8V - 2.49 K - 0.8V
Rset (K) = 10 K x Vout0.8V - 2.49 K - 0.8V
Rset (K) = 10 K x Vout0.8V - 1.82 K - 1.2V
www.murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
MPDTH_10 Series.A04 Page 5 of 6
MPDTH***10 Series
Adjustable Non-isolated 12/15-Amp POLA DC/DC Converters
APPLICATION NOTES
Tracking Input
When enabled, the tracking function allows the output to follow an external analog signal presented at the Tracking input. This pin becomes active approximately 50 mS after the input voltage has been applied and the converter reaches regulation. External track inputs must be referred to Ground. Several converters may be Tracked in parallel to generate outputs which rise and fall together. The Tracking input range is zero Volts up to the nominal set-point output voltage. If the Tracking input rises above the Vout nominal voltage, Vout will remain at the set point after the power up ramp. If Track is unused, it should be connected to +Vin. Please note that because of the Under Voltage input lockout feature (UVLO), the output cannot follow Track In during power up. Also, the Track feature is disabled whenever the converter is in Inhibit (OFF) mode.
[1] The pre-bias voltage must be lower than the expected final set-point output voltage. If the pre-bias voltage remains higher than the set-point and is capable of back-driving excess current, possible output damage may occur. If the pre-bias voltage has high impedance or has very limited current capability, normal startup will proceed. [2] Tracking operation must not be used during pre-bias startup. The Tracking input should be either open or connected to Vin so that normal soft start will proceed. After successful startup of approximately 50 mSec, Tracking may be resumed. [3] Carefully examine any output circuits with large external output capacitors and low-ESR. If there is no bleeder circuit or other method to reduce the stored voltage AND the cap voltage is higher than the expected set-point, operation may fail or the output may be damaged. Smaller capacitors with lower energy storage should not interfere with startup. See the recommended Connection Diagram. Use only as much output capacitance as needed. Also be careful immediately turning the converter back on after the Inhibit control turns the converter off. Any energy stored in larger output capacitors may cause the problems described above.
Over-Current Output Protection
If excess current is drawn from the converter, the output will shut down and then periodically attempt to restart with narrow full power cycles. If the excess load is reduced to within the rated maximum load, the converter will immediately restart and operate normally. If the load is still too great, another power-down cycle will begin. This is called "hiccup" operation. It significantly reduces the output power to avoid damage. The converter will quickly and automatically recover once the load is reduced.
Margin Up/Down Controls
Ground each Margin control to increase or decrease the output voltage by 5% from its setpoint value. If not needed, leave the margin controls unconnected (open). The margin controls are analog inputs and are not logic compatible. If a switch is not used to ground, a small signal transistor (such as an n-channel MOSFET with low off-state leakage) will work if biased fully into either pinchoff/ cutoff or saturation. Sink current is approximately -8 mA when ON and the open circuit voltage is approximately 0.8 Volts when OFF. Do not ground both margin controls simultaneously. For output changes less than 5%, insert an additional resistor in series with the switch or transistor to ground. The margin adjustment equation is: R-up or R-down (in K) = (499 / delta%) - 99.8 Where "delta%" is the desired change in percent of Vout up or down relative to the set-point output. Be sure to use low tempco precision resistors.
Pre-Bias Operation
The MPDTH_WAH/WAS series of converters use synchronous rectification in their output circuits. Normally, synchronous rectification may cause excess current being sunk back in to the converter if there is higher external output voltage present. If such prebias voltage is present on the output at the time of startup, the converter will operate in a manner which avoids excessive reverse current being sunk back into the output. This pre-bias protection will continue until the converter achieves normal regulation at its set-point output voltage. In order to achieve successful pre-bias voltage protection, several conditions must be met:
USA: Canada: UK: France: Germany: Japan: China: Singapore:
Mansfield (MA), Tel: (508) 339-3000, email: sales@murata-ps.com Toronto, Tel: (866) 740-1232, email: toronto@murata-ps.com Milton Keynes, Tel: +44 (0)1908 615232, email: mk@murata-ps.com Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: france@murata-ps.com Munchen, Tel: +49 (0)89-544334-0, email: munich@murata-ps.com Tokyo, Tel: 3-3779-1031, email: sales_tokyo@murata-ps.com Osaka, Tel: 6-6354-2025, email: sales_osaka@murata-ps.com Shanghai, Tel: +86 215 027 3678, email: shanghai@murata-ps.com Guangzhou, Tel: +86 208 221 8066, email: guangzhou@murata-ps.com Parkway Centre, Tel: +65 6348 9096, email: singapore@murata-ps.com
Technical enquiries email: sales@murata-ps.com, tel: +1 508 339 3000
Murata Power Solutions, Inc. 11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A. Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: sales@murata-ps.com ISO 9001 and 14001 REGISTERED
03/26/09
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. (c) 2009 Murata Power Solutions, Inc.
www.murata-ps.com
MPDTH_10 Series.A04 Page 6 of 6


▲Up To Search▲   

 
Price & Availability of MPDTH03010WAH

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X